{"product_id":"gb-draca-200-fully-automated-bio-chemistry-analyzer","title":"GB DRACA 200 Fully Automated Bio-chemistry Analyzer","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFully Automated Biochemistry Analyzer \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConstant 200 test\/hour with double reagent \u003c\/li\u003e\n\u003cli\u003e80 reagent position\u003c\/li\u003e\n\u003cli\u003eAutomatic liquid level sensing, anti-collision protection\u003c\/li\u003e\n\u003cli\u003eIntegrated full closed optical system, multi-wavelength simultaneous detection\u003c\/li\u003e\n\u003cli\u003eNew amorphous optical plastic reaction cups perfect transmittance\u003c\/li\u003e\n\u003cli\u003eMaintenance-free semiconductor solid-state refrigeration\u003c\/li\u003e\n\u003cli\u003eFriendly surface and easy to operation\u003c\/li\u003e\n\u003cli\u003eThe multifunction precision sampling probe\u003c\/li\u003e\n\u003cli\u003eExcellent mixer design \u003c\/li\u003e\n\u003cli\u003eHigh precision ceramic syringe \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTECHNICAL SPECIFICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 70.2247%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eMACHINE TYPE\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e Random Access with dedicated DRACA system packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eTEST SPEED\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e200 Test\/Hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eTEST PRINCIPLE \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003eColorimetric Method, Turbidimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eTEST METHOD\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e1 Point End,2 Point End, Fixed Time, Kinetics \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eCALIBRATION TYPE\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003eLinear \u0026amp; Nonlinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eREAGENT TRAY \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e80 Reagent positions (40 for R1 \u0026amp; 40 for R2), Non-stop cooling system with Peltier pad inside,24 Hours 2'c-14'c \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eREAGENT VOLUME \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e20-300μl, Step by 1\u003cspan\u003eμl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eREAGENT NEEDLE\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eLiquid Surface Detection, Timely Tracking for Liquid volume, collision Avoidance.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eOPERATING SYSTEM \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eWindows XP,7,8,10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eDATA PROCESSING \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calibration test combination\u003c\/li\u003e\n\u003cli\u003eEffective time management of reagents\u003c\/li\u003e\n\u003cli\u003eSerum index\u003c\/li\u003e\n\u003cli\u003eWhole process detection\u003c\/li\u003e\n\u003cli\u003eLinear expansion of enzyme\u003c\/li\u003e\n\u003cli\u003eBlank deduction\u003c\/li\u003e\n\u003cli\u003eDirty cuvette memory\u003c\/li\u003e\n\u003cli\u003eCross infection prevention\u003c\/li\u003e\n\u003cli\u003ePatient information memory and association input\u003c\/li\u003e\n\u003cli\u003eAutomatic report audit\u003c\/li\u003e\n\u003cli\u003eData fuzzy query \u003c\/li\u003e\n\u003cli\u003eReport statistics and printing\u003c\/li\u003e\n\u003cli\u003eReference range grading \u003c\/li\u003e\n\u003cli\u003eAlarm information classification\u003c\/li\u003e\n\u003cli\u003eUser operation privilege classification management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eREPORT PRINTING \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e6 Format, optional, support custom pattern\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eINTERFACE\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eTCP\/IP network interface \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eSAMPLE TRAY \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e40 Sample position\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eSAMPLE TUBE \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eMicro cup \u0026amp; Test tube \u0026amp; Blood collection tube can be used (12-13)mm*(25-100)mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eSAMPLE PROBE\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e2-30\u003cspan\u003eμL, Step BY 0.1μL\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eSAMPLE PROBE \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid surface detection\u003c\/li\u003e\n\u003cli\u003eTimely tracking for liquid volume\u003c\/li\u003e\n\u003cli\u003ecollision avoidance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eSAMPLE BARCODE \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eOPTIONAL \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eMIXER-PADDLE \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eType mixing, effective reducing of carryover\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eLIGHT SOURCE\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eHalogen lamp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eWAVELENGTH \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e340.405.45.505.546.578.630.700 (nm) 4 more options \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eABSORBANCE RANGE \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e0-4.0 Abs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eRESOLUTION\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e0.0001Abs-4.0 Abs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003ePOWER SUPPLY\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003eAC 110\/220V\u003cspan\u003e±10%,50\/60 Hz,650W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eWATER CONSUMPTION \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e8L\/Hours (Maximum)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eDIMENSION\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e870mm*690mm*740mm(L*W*H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eWEIGHT\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e80 Kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eREACTION TRAVY\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e44 Reaction cuvettes, new amorphous optical plastics reaction cups,perfect transmittance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eREACTION VOLUME \u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e50\u003cspan\u003eμL-30μL\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eREACTION TIME\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003e10 MINUTES\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15%;\"\u003eTEMPERATURE\u003c\/td\u003e\n\u003ctd style=\"width: 47.822%;\"\u003e\n\u003cp\u003ePeltier pad incubation system, reaction temperature (37'C \u003cspan\u003e± 0.1 'C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Genuine Biosystem","offers":[{"title":"Default Title","offer_id":32418047524939,"sku":"TTD007","price":855000.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0276\/9118\/8299\/products\/Draca-200.png?v=1591956968","url":"https:\/\/tentabs-test-site.myshopify.com\/products\/gb-draca-200-fully-automated-bio-chemistry-analyzer","provider":"Tentabs-test-site","version":"1.0","type":"link"}